You have a customer who is concerned with high CPU and disk utilization on their SnapMirror destination system. They are worried about high CPU and disk usage without any user operations. In this situation, what should you tell the customer?
A. Suggest that the customer manually cancel any scanners on the destination to reduce CPU usage.
B. Explain that background tasks such as SnapMirror throttle up in the absence of user workload.
C. Suggest that the customer throttle their SnapMirror relationships to reduce resource consumption.
D. Explain that only user workload should use the CPU and Investigate further.
After users start reporting the Inability to create new flies in a CIFS share, you find EMS events for wafl.dir.size.max logged for the volume of the SVM to which the share points.
In this scenario, which action should you take to solve this issue?
A. Delete unneeded files from the directory.
B. Move the volume to a different aggregate.
C. Increase the maximum numberof files for the volume.
D. Increase the maximum directory size for the volume.
Your customer Informs you about SnapMlrror problems after upgrading NetApp ONTAP software to a newer version. After investigating the event logs and the SnapMirror history, you see information about delayed updates of the SnapMirror relationships.
How would your customer prevent such problems in the future?
A. Quiesce the SnapMirror relationships before upgrading the ONTAP software.
B. Verify that the cabling of the hardware port that Is responsible for SnapMirror transfers Is correct.
C. Modify the schedules of the SnapMirror relationships after upgrading the ONTAP software.
D. Delete the SnapMirror relationships and create them new after upgrading the ONTAP software.
The motherboard of Node-01 is being replaced. To perform this task, a takeover was Initiated from Node-02. Node-02 panics showing the string below.
PANIC; Permanent errors on all HA mailbox disks (while marshalling header) in SKprocess fnmbx_instanceWorker on release 9.5P8 (C)
What has happened in this situation?
A. While in maintenance mode, the sldiag device show command was executed.
B. While in maintenance mode, the fcadmin device_map command was executed.
C. While in maintenance mode, the HA_config show command was executed.
D. While in maintenance mode, the mailbox destroy local command was executed.
A storage administrator reports that a monitoring toot is reporting that the storage controller reads between 90% to 93% CPU use. You run the sysstat -m command against thenode in question.
Referring to the exhibit, which statement is correct?
A. The customer should be advised to exclude certain workflows to reduce use.
B. High network exempt use could be a problem.
C. You should immediately investigate further bygathering perfstat data and opening a support case.
D. The CPU Is not a first-order monitoring metric for ONTAP.
You have a 2-node NetApp FAS2750 switchless cluster with twenty-four 1.8 TB disks that is experiencing performance issues. Upon investigation, you discover severaltype B consistency points.
Referring to the exhibit, which corrective action would address these consistency points?
A. Create additional data LIFs.
B. Convert the 2-node switchless cluster to a 2-node switched cluster.
C. Add an additional shelf oftwenty-four 1.8 TB disks.
D. Replace the twenty-four 1.8 TB disks with twelve 4 TB disks.
After expanding a two-node AFF A300 cluster with two AFF A700 nodes, you observe latencies when data is accessed indirectly. The system node run -node -command netstat command shows retransmits and packet drops on the LIFs. The AFF A700 nodes with 40 Gbps and the AFF A300 connect with 10 Gbps to the cluster interconnect. You are using Cisco Nexus 3132Q cluster interconnect switches. You just updated to ONTAP 9.8 software.
In this scenario, what is causing this problem?
A. The 10 Gbps to 10 Gbps cluster Interconnect is creating a speed mismatch.
B. AFF A300 and AFF A700 node mixing Isnot supported in ONTAP 9.8 software.
C. The AFF A300 Is using an adapter card for the cluster Interconnect, but only onboard ports are supported.
D. There is an NXOS firmware mismatch, verify in the Interoperability Matrix (1MTJ for a supportedversion.
You receive the panic message shown in the exhibit.
In this scenario, which component should you troubleshoot first?
A. the PCI card in slot 3
B. the MetroCluster FC-Vl card in slot 6
C. the memory module in slot 1
D. the CPU
You Just used the CLI to create a NetApp ONTAP FlexGroup Volume on a NetApp Cloud Volumes ONTAP instance. After creation, you notice odd behavior in NetApp Cloud Manager. In this scenario,what Is the reason for this behavior?
A. Cloud Volumes ONTAP does not support FlexGroup volumes.
B. The Capacity Management Mode within Cloud Manager should be set to Manual.
C. The Capacity Management Mode within Cloud Manager should be set to Automatic.
D. Cloud Manager must be used to provision the FlexGroup volume.
A customer with an FC MetroClusterconfiguration that is running NetApp ONTAP 9.8 software experienced a site outage and wants to know why the MetroClusler configuration did not switch over to the other site. What are two reasons for this problem? (Choose two.)
A. There was a failed PSU inthe switchover site.
B. The ISLs were down between the sites.
C. The site had unmirrored aggregates.
D. An ISL link was not operating at 16Gbps.