A customer is deploying a FlexPod Datacenter and planning to boot from SAN each their UCS blades using the Fibre Channel Protocol.
In this scenario, which three actions would accomplish their objective? (Choose three.)
A. Use only a pair of Cisco Nexus 9318YC-FX switches
B. Create an igroup on the NetApp ONTAP storage system with the appropriate IQNs
C. Use only a pair of Cisco Nexus 9336C-FX2 switches
D. Use a pair of Cisco MDS 9148T and a fair of Cisco 9336C-FX2 switches together
E. Create an igroup on the NetApp ONTAP storage system with the appropriate WWPNs
A customer is designing a FlexPod solution that must satisfy the requirements shown below:
-- have disaster recovery to an alternative data center,
-- must have continuous replication of data for a database,
-- must leverage a 100Gbps capable switch,
-- have a maximum distance of 700 km.
In this scenario, which two components would be used to satisfy the requirements? (Choose two.)
A. MetroCluster FC
B. Cisco Nexus 3232C
C. MetroCluster IP
D. Cisco MDS 9132T
A customer has decided to deploy Red Hat OpenShift on a FlexPod solution, based in a published Cisco Validated Design. The customer intends to use the NetApp Trident to attach persistent storage to the customer's containers from the customer's NetApp AFF controllers.
In this scenario, which two storage protocols are supported? (Choose two.)
A. iSCSI
B. FC
C. NFS
D. SMB
A customer has a FlexPod configuration that supports FC and uses Cisco MDS switches. The customer wants to add a 48-Port 32 Gbps Advanced Fibre Channel Switching blade to support both 32 Gbps FC and 32 Gbps NVMe-oF.
In this scenario, which Cisco switch is appropriate?
A. MDS 9250i
B. MDS 9706
C. MDS 9148S
D. MDS 9396S
A customer wants to add 40 Gbps networking capabilities to a FlexPod Datacenter 10 Gbps environment. Which two Cisco components support this speed? (Choose two.)
A. Cisco Nexus 9504
B. Cisco UCS 1440 VIC
C. Cisco Nexus 3550-F
D. Cisco UCS 1455 VIC
A customer with a FlexPod solution wants to expand their NetApp ONTAP 9.7 switchless cluster. The new hardware must support expansion slots. In addition, they will also upgrade to a 100 Gbps-capable cluster interconnect switch for future growth.
In this scenario, which two additional components will satisfy the requirement? (Choose two.)
A. Nexus 3232C
B. Nexus N3132Q-V
C. NetApp FAS2720
D. NetApp AFF A400
Your customer wants to change from local boot to SAN boot for the compute layer. What must be present on the network layer to meet the customer's design change?
A. NFS
B. CIFS
C. IQN
D. FC
An administrator wants to ensure secure authentication while accessing a NetApp ONTAP system.
In this scenario, which two access methods should be used? (Choose two.)
A. RSH
B. SSH
C. HTTPS
D. HTTP
A customer wants to refresh their FlexPod solution by moving from 10 Gbps to 40 Gbps networking. They use FCoE to boot from SAN.
In this scenario, which statement is true?
A. FCoE is supported for 32 Gbps adapters
B. FCoE is supported for 25 Gbps adapters
C. FCoE is supported for 40 Gbps adapters
D. FCoE is supported on only 10 Gbps unified adapters
During a design meeting, a customer states that their goal is to deliver continuous availability across both network and storage during business continuity events. The customer has two data centers that are 80 km apart, and they want the configuration to be as logically unified across both sites as possible.
In this scenario, which FlexPod data protection solution achieves this goal?
A. FlexPod with NetApp Cloud Sync
B. FlexPod with NetApp SnapCenter
C. FlexPod with NetApp MetroCluster IP
D. FlexPod with NetApp FabricPool