A customer placed a service call after installing genuine HP memory from a ProLiant DL380 Gen7 server into a new ProLiant DL380 Gen8 server and receiving a POST message that the memory is not HP Smart Memory.
What caused this to happen?
A. The memory is defective and is not discovered during POST.
B. The memory is not in the correct processor Bank.
C. Only Gen8 memory can be detected as Smart Memory.
D. The memory is not authentic HP memory.
An administrator needs to extend the runtimes for a company's critical devices in case of utility power failure.
Which HP management software should the administrator use to configure the power failure settings on the company's HP UPS?
A. HP Systems Insight Manager HP SIM)
B. HP UPS Power Protecting Agents
C. HP Power Protector
D. HP Insight Power Control
An engineer repaired a memory problem in a ProLiant BL460c Gen8 server blade running Windows 2008 R2. What should the engineer do to verify the repair? (Select two.)
A. Observe the Insight Display at the front of the server after it boots.
B. Check the Active Health System.
C. Observe the server console for POST errors.
D. Reboot the BL460c Gen8 server and run the offline Insight Diagnostics.
E. Reseat the memory and inform the customer when the job is done.
Where is the data written when power is lost on an HP Smart Array controller?
A. Master boot record
B. Flash backed write cache
C. Network controller
D. System memory
Which RAID level is known as Advance Data Guarding (ADG)?
A. RAID 1
B. RAID 5
C. RAID 6
D. RAID 10
Which feature should you enable in RBSU in a ProLiant Gen8 server lo reduce processor power usage and improve overall performance in some applications?
A. OS Control Mode
B. Processor Core Disable
C. Intel Hyper-Threading
D. HP Dynamic Power Savings Mode
Which components are integrated into the HP Service Pack for ProLiant (SPP)? (Select three)
A. HP Advanced Diagnostic Utility
B. HP Smart Update Firmware DVD
C. HP Advanced Configuration Utility
D. HP ProLiant Support Packs
E. HP Smart Update Manager
F. HP ProLiant Version Control DvD 24 of 60
A customer asks you to check on the remaining life of the solid state disk drives. Where can you access the SMARTSSD Wear Gauge?
A. Array Configuration Utility (ACU)
B. Option ROM Configuration for Arrays (ORCA)
C. iLO home page
D. Integrated Management log (IML)
You cannot get to the network from any of the server blades in a c7000 enclosure with 10GbE Pass-Thru modules.
What should you verify first for proper connectivity to the network?
A. Correct SFPs are installed
B. External switch supports at least Gigabit speed
C. Interconnect link between the Pass-Thru modules
D. External switch set to half duplex
After you replace the system board in a ProLiantBL460c G8 server blade,the server cannot conned to an external shared storage through the SAS interface. Other similar servers in the same enclosure are in working condition. What should you check to verify that the physical hardware connectivity it connected?
A. External storage power status
B. ACU of the server blade for storage status
C. Server bladeiLO tot hardware information detected by the management processor
D. Server blade port mapping for theIOmodule connectivity to the interconnect module