Which HP web-based tool can be used to configure a solution of servers, storage and networking along with services, allowing an export of the final solution?
A. Sizing Tool for VMware vSphere
B. Simplified Configuration Environment
C. Sizer for Microsoft Hyper-V R2
D. Enterprise Configurator Workbench
A customer Installed Insight server deployment on a server that also hosts the DHCP server. Which option is required on the DHCP server for HP Insight Control server deployment to register PXE clients?
A. Option 5 name Server
B. Option 15 Domain Name
C. Option 50 Address Request
D. Option 60 Class ID
A consultant must provide a UPS solution to support the load requirement of a server solution being delivered. What is the recommended tool to use to provide the correct UPS solution?
A. HP Rack and Power Sizer (upssizer.com)
B. HP Value UPS Manager
C. HP Rack and Power manager
D. HP Power Advisor
You configured disk thresholds for all servers running Windows Server 2008 R2. You want HP SIM to react by running a script that will delete all IE temporary files on the server that reports problems with the available capacity on the drive. What do you have to configure from the HP SIM level to achieve this?
A. Configure the Single Sign On feature for all the servers that should be covered that script.
B. Establish a trust relationship between HP SIM and all servers covered by that script, and apply the Insight Control licenses.
C. Create a custom command that will delete temporary files and configure an automatic event handling task to run this script when a specific event occurs.
D. Import the HP SIM certificate to the HP System Management homepage for all of the servers that should be covered by that script and configure SNMP security to allow remote command execution.
To help diagnose issues, which new HP ProLiant Gen8 server feature ensures that Support knows that has changed in a server?
A. Agentless Management Service
B. Complex Programmable Logic Device
C. Integrated Active Health System
D. Associated Targets Detections
A customer is running several ESXi 5.0 servers and complains the workload is not properly balanced between the hosts even through the DRS cluster is configured. What should you verify?
A. EVC configured on the cluster level
B. Host monitoring configuration on the cluster level
C. Balloon driver activity ESXi hosts
D. Automation level configured on the cluster level
Which Windows performance counters must be monitored to determine if a processor is overloaded?
A. Processor: % Processor Time and system: Processes
B. Processes: % Processor Time and system: Processor Queue length
C. Processor\% Processor Time and system\Processor Queue Length
D. Disk: Average Disk Queue Length and system: Processor Queue length
A Microsoft Windows customer wants to add a file server presence to several existing and future remote sites. Redundancy, ease of management and hot swap storage growth capabilities beyond 32TB are required.
The solution must support iSCSI, FTP, and WebDAV for each site. Footprint and cost are concerns. What is the best solution?
A. X5000 running Windows Storage Server, D2700 enclosure
B. Four SL230p Gen8 nodes running Windows 2008 R2, SL6500 and ILO advanced licensing
C. Two DL360p Gen8 servers running Windows Storage Server and a D2600 enclosure
D. C7000, four BL460c Gen8 blades running Windows 2008 x64 and an MDS600
Which event default actions can you configure using the Automatic Event Handling feature of HP SIM? (Select two)
A. Run the identity task
B. Forward as an SNMP trap
C. Shut down the server
D. Restart Insight Management Agents
E. Assign the event to the user
You are unable to get basic information about the server during the discovery phase in HP SIM. What should you verify first?
A. if the HP SIM certificate is applied to the managed machine
B. If the server is enabled to accept SNMP packets from the HP SIM server
C. If the managed system has the management processor discovered first