A customer using a VMAX 20K containing 2 standard storage bays, each containing 90 drives wants to expand their capacity to 120 drives. What is the least expensive way to expand the existing configuration, but still a good choice for optimal performance in this configuration?
A. Add four DAEs to each storage bay, each containing 15 drives
B. Add eight DAEs to the first storage bay, each containing 15 drives
C. Add two storage bays, one to each loop and each bay containing four DAEs with 15 drives each
D. Add one storage bay containing eight DAEs with 15 drives each to the first loop
You are installing a VMAX 40K with dispersed System Bay.
Which length cables are required to provide back-to-back separation?
A. 25M
B. 10M
C. 3.6M
D. 20M
How does the Service Processor communicate with all 8 engines in a VMAX 20K?
A. Ethernet cables are directly connected to Management Modules in engine 8 and engine 1, which are daisy chained to the other six engines.
B. Ethernet cables are directly connected to Management Modules in engine 4 and engine 5, which are daisy chained to the other six engines.
C. Ethernet cables are directly connected to each Management Module in each engine.
D. Ethernet cables are directly connected to the Management Modules in engine 4 which is daisy chained to the other seven engines.
Which two System Bays use the same component layout when fully populated?
A. VMAX 10K 3 and 4
B. VMAX 10K 1 and 2
C. VMAX 10K 1 and 4
D. VMAX 10K 2 and 4
What is the default folder where SymmWin 5876 is installed?
A. C:\SymmWin
B. C:\Program files\EMC\SymmWin\5876
C. C:\SymmWin\5876
D. C:\Program files\EMC\SymmWin
Where in SymmWin can the Secure Erase feature be enabled or disabled?
A. IMPL Init
B. Feature Registration
C. Edit Directors
D. IMPL Browser
What is a SymmWin Best Practice when configuring disk drives?
A. Smaller drives perform better.
B. Go deep then wide when adding drives.
C. Protection type is irrelevant.
D. Use Raid 5 instead of Raid 6 when data availability is secondary.
Which RAID 6 configuration is supported by Symmetrix?
A. RAID 6 (14+2)
B. RAID 6 (14+1)
C. RAID 6 (7+1)
D. RAID 6 (4+2)
Refer to the Exhibit.
While configuring a Multi-Engine VMAX 20K, the CE is connecting Engine numbers 4 and 5 with cables. What is the type and sequence of connections required to connect the Highest Engine number?
A. Purple Cable; connects B to C and A to 1
B. Green Cable; connects B to C and A to 1
C. Purple Cable; connects B to C and D to 1
D. Green Cable; connects B to C and D to 1
Refer to the exhibit.
For what is the ELM tool used?
A. Manage Symmetrix Licenses
B. Environmental LCC Management
C. ELM scheduler task
D. Create Environmental scripts