Which protocol is used to provide block storage connectivity in a Vblock® System 200?
A. FCoE
B. NFS
C. iSCSI
D. FC
An existing customer wants to add external IP addresses to its management pool. Which element manager would you recommend?
A. Data Center Network Manager
B. Unisphere
C. VCE VisionTM Intelligent Operations
D. UCSM
You are configuring storage groups for new ESXi hosts residing on a Vblock® System 200. A customer has asked for storage separation across virtual machines.
Where should the VMFS configured LUNs reside?
A. In the same storage group where the boot from the SAN LUN resides
B. In a single storage group with all the other ESXi hosts
C. In multiple storage groups configured for each host
D. In a single storage group configured for the control station
A company wants to ensure that they monitor the amount of storage used by thin provisioned VMs. What should be used to accomplish this task?
A. vCenter VM Edit Settings menu
B. vCenter storage maps
C. vCenter storage reports
D. vCenter hardware status page
You are using the default settings for VCE VisionTM Intelligent Operations. Three minutes after an event is reported in UCSM, it is still not reported in Vision.
Which statement is correct?
A. Verify the network connection between the system library virtual machine to the UCSM's virtual IP address.
B. VCE VisionTM software login credentials on vCenter may be incorrect.
C. Verify your HTTP settings in UCSM.
D. VCE Vision software is operating as expected.
A company wants to track every fault on UCS that UCSM declares as "should be fixed immediately." Which fault level is the lowest level to track?
A. Warning
B. Major
C. Critical
D. Minor
You have added physical disks to your Vblock® System 720 to a physical disk group and then created data devices.
What must you do to see the new capacity?
A. Add the devices to the masking group.
B. Map the devices to the front end ports.
C. Add the devices to the thin pool and enable them.
D. Add the devices to the FAST VP policy.
Click the Exhibit button. -- Exhibit -
-- Exhibit -You are adding a new VM within vCenter when the error shown in the exhibit occurs.
What does this error indicate?
A. The Standard vSwitch has run out of ports.
B. The Standard vSwitch has run out of port licenses.
C. The Nexus 1000V switch has run out of port licenses.
D. The Nexus 1000V switch has run out of ports.
What are two reasons a Vblock® System administrator would use the Release Certification Matrix? (Choose two)
A. Introduce new component support.
B. Document end-of-life component support.
C. Upgrade software levels to resolve problems.
D. Identify known problems with specific code revisions.
How do you create a log bundle for the Nexus 1000V virtual switch module (VSM)?
A. Use the vCenter client to generate a VMware support bundle.
B. Execute the vem-support all command from the shell on each ESXi host.
C. Run the show tech-support svs > bootflash:techsupport.log command from the VSM shell.
D. Use the Java-based Nexus 1000V log bundle creator on the element manager.