You are configuring a VEE group to include rules to be executed when loading the initial measurement data (IMD).
What is the VEE group directly associated with?
A. Device Type and Measuring Component Type
B. Measuring Component Type
C. Device Type
D. Usage Type
E. Device Configuration Type
Your client has installed scalar devices to measure the solar energy generated (Export) and the energy received (Import) from the National Grid. This data is stored in separate measuring components (registers).
The validation rules are generally the same for both measuring components, but there is one exception. The Negative Consumption check applies only to energy received (import). Which two are possible configurations resulting in the Negative Consumption rule being checked for energy received (import) only? (Choose two.)
A. Modify the base VEE rule.
B. Remove the Negative Consumption check from the VEE group.
C. Create two different VEE groups.
D. Use Eligibility Criteria.
E. Use the Skip Flag in the VEE rule.
How do you ensure that specific Validation, Editing, and Estimation (VEE) rules are applied to estimated measurements?
A. by adding the VEE Group to the Device Configuration Type
B. by adding the estimation rules to the Manual Override VEE Group to the Measuring Component Type
C. by adding the VEE Group to the Device Type
D. by adding the VEE Group as the Fallback VEE Group for the appropriate VEE role
Which configuration steps are required to derive loss-adjusted kWh on a measuring component based on a loss factor value related to a service point?
A. Configure a Service Point Characteristic Type and derivation algorithm, and then associate the algorithm to the Measuring Component Type and the characteristic value to the service point.
B. Configure an SQI and the derivation algorithm, and then associate the algorithm to the Measuring
Component Type and SQI to the service point.
C. Configure a factor and derivation algorithm, and then associate the factor to the Measuring Component Type and the derivation algorithm to the service point.
D. Configure a factor and derivation algorithm, and then associate both to the Measuring Component Type and service point.
E. Configure a Service Point Characteristic Type, factor, derivation algorithm, and Service Quantity Identifier (SQI), and then associate the SQI and derivation algorithm to the Measuring Component Type and the characteristic value to the service point.
Which entity defines the type of collection process to start based on age of debt, amount of debt, and type of customer?
A. Debt Class
B. Customer Class
C. Collection Class Control
D. Collection Class
E. Collection Process Template
When the source of a Financial Transaction is canceled, what does it result in?
A. The source Financial Transaction is deleted and a new reversal Financial Transaction is created.
B. A new reversal Financial Transaction is created.
C. The source Financial Transaction status is changed to "Canceled".
D. The source Financial Transaction is deleted.
E. No change occurs.
Measuring components are either subtractive or consumptive. Which statement correctly describes these two concepts?
A. Subtractive measuring components are associated only with water service, whereas consumptive measuring components are for gas and electric services.
B. Subtractive measuring components are used to measure demand, whereas consumptive measuring components are used to measure how much was consumed since the previous reading.
C. Subtractive measuring components are associated with deductive meters, whereas consumptive
measuring components are not.
D. A subtractive measuring component's consumption for a given period of time is the end measurement minus the start measurement. A consumptive measuring component's consumption is simply the measurement itself, and represents the consumption for the period of time since the previous measurement was taken.
A usage subscription must exist before usage transactions can be calculated for a specific service point.
Where do you configure the usage recipient?
A. in the Usage Rule Type
B. in the Service Point Type
C. in the Device Type
D. in the Measuring Component Type
E. in the Usage Subscription Type
How many Tenders can a Payment Event have?
A. one Tender per Payment Event
B. one Tender for each account the payment is applied to
C. one Tender for each form of Payment submitted
D. no Tenders for Payment Events, only Payment Segments
E. no Tenders for Payment Events, only Payments
In addition to sets of procedures, and careful handling instructions for hazardous or delicate materials, what can Specifications include to provide information about assets or other entities?
A. Attributes
B. Specifications
C. Rules D. Conditions